Single Disc Grinder & Polisher GHEXA-GRP-EQP-AUT-011
| Parameter | Specification |
|---|---|
| Model | GHEXA-GRP-EQP-AUT-011 |
| Working Disc Diameter | 8″ (203 mm) / 10″ (254 mm) |
| Disc Speed | 50–600 rpm (stepless) |
| Rotation Direction | CW / CCW |
| Torque | 10 N·m |
| Motor Type | Servo motor |
| Rated Power | 750 W |
| Rated Current | 4 A |
| Power Supply | 220 V / 50 Hz (110 V / 60 Hz customization available) |
| Control Panel | Tempered glass touch panel |
| Preset Speeds | 3 fixed speeds |
| Timing / Countdown Function | Yes |
| Water Supply Max Pressure | < 0.3 MPa |
| Inlet Connector | G 3/4 external thread |
| Outlet Diameter | OD Φ32 mm (1-1/4 inch) |
| Circulating Water Tank | Optional |
| Noise Level (at 1 m) | < 50 dB |
| Construction | ABS molded shell; Fully sealed working tray |
| Cleaning Features | Retractable faucet; Tool-free disc disassembly |
| Operating Environment | Temperature: -20 °C to 60 °C; Humidity: 0–95% RH |
| Dimensions (W × D × H) | 380 × 657 × 270 mm |
| Weight | 20 kg |
Payment. Payment upon receipt of goods, Payment by card in the department, Google Pay, Online card, -5% discount in case of payment
Warranty. The Consumer Protection Act does not provide for the return of this product of proper quality.
Description
Single Disc Grinder & Polisher GHEXA-GRP-EQP-AUT-011
The GHEXA-GRP-EQP-AUT-011 is a compact, high-performance single-disc grinder and polisher designed for efficient and precise metallographic sample preparation in space-constrained laboratories. Featuring an 8″ (203 mm) or 10″ (254 mm) disc, a powerful servo motor that maintains 10 N·m torque even at low speeds, a modern tempered glass touch panel, fully sealed working tray, retractable faucet, and tool-free disc removal, it combines ease of use, durability, and excellent surface quality. With stepless speed control (50–600 rpm), three preset speeds, and timing function, this machine is the ideal entry-to-mid-level solution for grinding and polishing metals, alloys, ceramics, composites, and coatings in research, teaching, and quality control environments.
Specifications
| Parameter | Specification |
|---|---|
| Model | GHEXA-GRP-EQP-AUT-011 |
| Working Disc Diameter | 8″ (203 mm) / 10″ (254 mm) |
| Disc Speed | 50–600 rpm (stepless) |
| Rotation Direction | CW / CCW |
| Torque | 10 N·m |
| Motor Type | Servo motor |
| Rated Power | 750 W |
| Rated Current | 4 A |
| Power Supply | 220 V / 50 Hz (110 V / 60 Hz customization available) |
| Control Panel | Tempered glass touch panel |
| Preset Speeds | 3 fixed speeds |
| Timing / Countdown Function | Yes |
| Water Supply Max Pressure | < 0.3 MPa |
| Inlet Connector | G 3/4 external thread |
| Outlet Diameter | OD Φ32 mm (1-1/4 inch) |
| Circulating Water Tank | Optional |
| Noise Level (at 1 m) | < 50 dB |
| Construction | ABS molded shell; Fully sealed working tray |
| Cleaning Features | Retractable faucet; Tool-free disc disassembly |
| Operating Environment | Temperature: -20 °C to 60 °C; Humidity: 0–95% RH |
| Dimensions (W × D × H) | 380 × 657 × 270 mm |
| Weight | 20 kg |
Key Applications & Uses
- Routine grinding and polishing of metallographic specimens (metals, alloys, ceramics, composites, coatings) in university teaching labs and small-to-medium research facilities
- Preparation of flat, scratch-free surfaces for optical microscopy, microhardness testing, and basic microstructure analysis
- Daily sample preparation in quality control, incoming inspection, and failure analysis laboratories with moderate throughput
- Processing of small to medium-sized mounted or unmounted specimens requiring consistent and reproducible results
- Supporting materials science education, entry-level R&D, pharma (implant material checks), biotech (biomaterial surfaces), and industrial labs needing a compact, reliable grinder-polisher
- Ideal for labs with limited bench space that still require professional-grade performance and ease of maintenance
Why Choose from G-Hexa?
- Compact Yet Powerful — Small footprint with a high-torque servo motor delivering stable 10 N·m performance even at low speeds—perfect for space-limited labs without sacrificing capability.
- User-Friendly Touch Control — Modern tempered glass touch panel with stepless speed adjustment, three preset speeds, and timing/countdown function makes operation intuitive and efficient for all users.
- Hassle-Free Maintenance — Fully sealed tray prevents water ingress, retractable faucet enables quick rinsing, and tool-free disc removal simplifies cleaning and abrasive changes.
- Durable & Quiet Design — ABS molded shell, stainless steel components, and noise level <50 dB ensure long service life and comfortable operation in shared or teaching environments.
- Flexible & Future-Proof — Supports both 8″ and 10″ discs, optional recirculating tank, and customizable voltage (110 V/60 Hz) to fit diverse lab requirements and regional power standards.
- Complete G-Hexa Support — Backed by G-Hexa’s full range of metallographic consumables, fast delivery across India, competitive pricing, and expert technical assistance for researchers, universities, pharma, biotech, and industrial users.
Frequently Asked Questions (FAQs)
Q: What disc sizes does the GHEXA-GRP-EQP-AUT-011 support? A: It accommodates both 8″ (203 mm) and 10″ (254 mm) discs, giving flexibility for different sample sizes and throughput needs.
Q: Does the motor maintain performance at low speeds? A: Yes—the servo motor provides a constant 10 N·m torque even at 50 rpm, ensuring smooth and effective grinding/polishing without stalling or loss of power.
Q: How easy is it to clean and change discs? A: Extremely convenient—discs can be removed without tools, the retractable faucet allows fast rinsing, and the fully sealed tray prevents water from entering the machine.
Q: Is the machine suitable for teaching labs or shared spaces? A: Absolutely—its compact size, quiet operation (<50 dB), simple touch panel, and durable construction make it ideal for educational environments and multi-user facilities.
Q: Can it run for long periods without overheating? A: Yes—the servo motor and automatic temperature-sensing cooling system support extended operation, especially at lower speeds commonly used in polishing.
Q: What water supply is required? A: It needs a standard lab water line with max pressure <0.3 MPa (inlet G 3/4 thread, outlet Φ32 mm). An optional recirculating water tank is available for closed-loop use.
Q: Is it suitable for both grinding and polishing steps? A: Yes—the wide 50–600 rpm range, directional control, and robust torque make it effective for the entire metallographic sequence from coarse grinding to fine polishing.












Reviews
There are no reviews yet.